Optimization Design of Noise in a Certain Rotor Oil Pupm Assembly
DOI:
https://doi.org/10.54691/xy8yxz90Keywords:
Rotor Oil Pump; Noise Optimization; Oil Pump Optimization; Noise Mechanism.Abstract
To solve the noise problem of a certain rotor oil pump during the experimental process, this article analyzes the source and characteristics of noise through the oil pan noise spectrum obtained from engine bench experiments and the noise mechanism of the oil pump; Targeted noise improvements have been made to the design of the rotary oil pump based on the source of noise. The experimental results showed that after the structural adjustment of the rotary oil pump was implemented, there was no significant change in the pressure fluctuation in the trapped oil area, but the noise was significantly reduced. This indicates that the optimization scheme has successfully improved the overall acoustic performance of the oil pump, providing a new direction for similar structural acoustic optimization.
Downloads
References
[1] Pang Jian, Chen Gang, He Hua. Automotive Noise and Vibration - Theory and Application [M]. Beijing: Beijing Institute of Technology Press, 2011.
[2] Guo Hongyuan, Chen Likui, Chen Rongjun. Development of Analysis of Trapped Oil Noise in Gear Oil Pumps [C]/Proceedings of the 2018 Annual Meeting of the Chinese Society of Automotive Engineers. Shanghai: 2018 Chinese Society of Automotive Engineers, 2018: 1106-1109.
[3] Lv Jianzhong, Zhang Jie, Liu Ming, et al. Experimental study on noise optimization of a commercial vehicle rotor oil pump [J]. Internal Combustion Engine and Accessories, 2020 311 (11): 55-57.
[4] Li Yanpeng, Pan Lingling, Yu Lei, et al. Order noise analysis and improvement of rotary oil pump [J]. Small Internal Combustion Engine and Vehicle Technology, 2019, 48 (02): 69-74.
[5] Ma Fuyin. Vibration and Noise Analysis of Automotive Engine Oil Pump [D]. Shanghai University of Engineering and Technology, 2012.
[6] Fu Xi, Zhan Qiang, Zhang Junhong. Research on noise optimization of a certain engine rotor oil pump assembly [J]. Modern Manufacturing Engineering, 2022, (04): 15-20. DOI: 10.16731/j.cnki.1671-3133.2022.04.03.
[7] SANG H L,KWAK H S,HAN G B, et al.Design of Gerotor Oil Pump with 2-Expanded Cardioids Lobe Shape for Noise Reduction [J].Energies,2019,12: 1126.
[8] FROSINA E,SENATOREA,BNONO D,et al.A Tridimensional CFD Analysis of the Oil Pump of a High Performance Motorbike Engine [J]. Energy Procedia,2014,45: 938-948.
[9] Ye Xianzhi. Structural design and flow field characteristics simulation analysis of circular arc cycloidal rotor pump [D]. Chongqing University, 2012.
[10] Singhal Ashok K, Athavale Mahesh M, Li Huiying, Jiang Yu. Mathematical Basis and Validation of the Full Cavitation Model [J]. Journal of Fluids Engineering, 2002, 124(3): 79-86.